CVE-2022-47936
Estado: ModificadaAlta (7.8)—
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 12
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-47936",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-47936",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-03-20T20:07:21.772715Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "JT Open",
"versions": [
{
"status": "affected",
"version": "All versions < V11.2.3.0"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "JT Utilities",
"versions": [
{
"status": "affected",
"version": "All versions < V13.2.3.0"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Parasolid V34.0",
"versions": [
{
"status": "affected",
"version": "All versions < V34.0.252"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Parasolid V34.1",
"versions": [
{
"status": "affected",
"version": "All versions < V34.1.242"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Parasolid V35.0",
"versions": [
{
"status": "affected",
"version": "All versions < V35.0.170"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Parasolid V35.1",
"versions": [
{
"status": "affected",
"version": "All versions < V35.1.150"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-02-14T11:15:14.473",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
}
],
"lastModified": "2026-06-17T05:14:28.630",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "33C7875E-FA42-4163-9395-B5A06E698328",
"versionEndExcluding": "11.2.3.0"
},
{
"criteria": "cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7300A3A0-744A-4D5A-A1CD-D83A1FE97A0B",
"versionEndExcluding": "11.2.3.0"
},
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F0D9079D-6138-4602-A982-9BC4ECBC35E7",
"versionEndExcluding": "34.0.252",
"versionStartIncluding": "34.0"
},
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4C486991-A1C0-4815-AAD6-163464D711AA",
"versionEndExcluding": "34.1.242",
"versionStartIncluding": "34.1"
},
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EA2114FD-BB07-4C24-98B1-928A510565BB",
"versionEndExcluding": "35.0.170",
"versionStartIncluding": "35.0"
},
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5C98612B-63DF-473C-AF6E-CF3740356D5B",
"versionEndExcluding": "35.1.150",
"versionStartIncluding": "35.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}