« Volver al listado

CVE-2022-46680

Estado: ModificadaCrítica (9.8)—

A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (5)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-46680",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-46680",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-21T15:05:13.390998Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "PowerLogic ION9000",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to 4.0.0"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "PowerLogic ION7400",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to 4.0.0"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": " PowerLogic PM8000",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to 4.0.0"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "PowerLogic ION8650",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "PowerLogic ION8800",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "Legacy ION products",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-05-22T14:15:09.433",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-03.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-03.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"
    }
  ],
  "lastModified": "2026-06-17T05:12:11.013",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "50C920E5-0F21-4DBB-9D0E-424F8C1A9B85",
              "versionEndExcluding": "4.0.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6718EAAA-074D-4807-AC2D-DD0A06D397FB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E43DFCA4-7ED0-4E61-872A-ECD08659A52B",
              "versionEndExcluding": "4.0.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4A560510-3A07-4EBB-8E2D-E473EE9B59C9",
              "versionEndExcluding": "4.0.0"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7EFB1251-11AE-4A77-AB68-26D6B58C8F33"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "46E8E79E-6DA7-4094-9622-3B91D5913493"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}