CVE-2022-46664
Status: ModifiedHigh (8.1)—
A vulnerability has been identified in Mendix Workflow Commons (All versions < V2.4.0), Mendix Workflow Commons V2.1 (All versions < V2.1.4), Mendix Workflow Commons V2.3 (All versions < V2.3.2). Affected versions of the module improperly handle access control for some module entities.
This could allow authenticated remote attackers to read or delete sensitive information.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
- Base score: 8.1
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.71%
- Percentile among all scored CVEs: 52
- Score date: 10/7/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-284
- NVD-CWE-Other
References
Raw JSON (NVD)
Show
{
"id": "CVE-2022-46664",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-46664",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-04-18T15:21:08.630592Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Mendix Workflow Commons",
"versions": [
{
"status": "affected",
"version": "All versions < V2.4.0"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Mendix Workflow Commons V2.1",
"versions": [
{
"status": "affected",
"version": "All versions < V2.1.4"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Mendix Workflow Commons V2.3",
"versions": [
{
"status": "affected",
"version": "All versions < V2.3.2"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2022-12-13T16:15:26.040",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-210822.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-210822.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix Workflow Commons (All versions < V2.4.0), Mendix Workflow Commons V2.1 (All versions < V2.1.4), Mendix Workflow Commons V2.3 (All versions < V2.3.2). Affected versions of the module improperly handle access control for some module entities.\r\n\r\nThis could allow authenticated remote attackers to read or delete sensitive information."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Mendix Workflow Commons (todas las versiones < V2.4.0), Mendix Workflow Commons V2.1 (todas las versiones < V2.1.4), Mendix Workflow Commons V2.3 (todas las versiones < V2.3.2) . Las versiones afectadas del módulo manejan incorrectamente el control de acceso para algunas entidades del módulo. Esto podría permitir a atacantes remotos autenticados leer o eliminar información confidencial."
}
],
"lastModified": "2026-06-17T05:12:09.857",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:mendix_workflow_commons:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "681A5F97-59C5-460C-B769-6B54E9E51F4E",
"versionEndExcluding": "2.4.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}