« Volver al listado

CVE-2022-43110

Estado: AplazadaCrítica (9.8)—

Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vector CVSS (AV:N, AC:L, PR:N, UI:N) indica explotación remota sin autenticación (T1190). Impactos: cambio de contraseña de admin y acceso no autenticado (T1078), configuración de comandos OS (T1059), y modificación de configuración del sistema (T1565.001).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (2)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-43110",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-43110",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-08-22T20:23:45.457505Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2025-08-22T20:15:31.777",
  "references": [
    {
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-182-05",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.ready2disclose.com/vpow-31491-43110/",
      "source": "cve@mitre.org"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        },
        {
          "lang": "en",
          "value": "CWE-306"
        },
        {
          "lang": "en",
          "value": "CWE-425"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down."
    },
    {
      "lang": "es",
      "value": "Voltronic Power ViewPower (versión 1.04-21353) y PowerShield Netguard (versión anterior a 1.04-23292) permiten a un atacante remoto configurar el sistema mediante una interfaz web no especificada. Un atacante remoto no autenticado puede realizar cambios en el sistema, como cambiar la contraseña de administrador de la interfaz web, ver/modificar la configuración del sistema, enumerar y apagar los dispositivos UPS conectados. Esto incluye la posibilidad de configurar los comandos del sistema operativo que deben ejecutarse si el sistema detecta que un UPS conectado se apaga."
    }
  ],
  "lastModified": "2026-06-17T05:05:56.180",
  "sourceIdentifier": "cve@mitre.org"
}