CVE-2022-42974
In Kostal PIKO 1.5-1 MP plus HMI OEM p 1.0.1, the web application for the Solar Panel is vulnerable to a Stored Cross-Site Scripting (XSS) attack on /file.bootloader.upload.html. The application fails to sanitize the parameter filename, in a POST request to /file.bootloader.upload.html for a system update, thus allowing one to inject HTML and/or JavaScript on the page that will then be processed and stored by the application. Any subsequent requests to pages that retrieve the malicious content will automatically exploit the vulnerability on the victim's browser. This also happens because the tag is loaded in the function innerHTML in the page HTML.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L
- Puntuación base: 4.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.17%
- Percentil entre todas las CVEs puntuadas: 5
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-42974",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-42974",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-06-25T20:08:24.651332Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 1.3
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:kostal_piko:mp_plus_hmi_oem:*:*:*:*:*:*:*:*"
],
"vendor": "kostal_piko",
"product": "mp_plus_hmi_oem",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "1.0.1"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-06-21T22:15:10.557",
"references": [
{
"url": "https://medium.com/%40daviddepaulasantos/how-we-got-a-cve-for-a-dom-based-stored-xss-on-a-solar-panel-917b9d7b2545",
"source": "cve@mitre.org"
},
{
"url": "https://medium.com/%40daviddepaulasantos/how-we-got-a-cve-for-a-dom-based-stored-xss-on-a-solar-panel-917b9d7b2545",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Kostal PIKO 1.5-1 MP plus HMI OEM p 1.0.1, the web application for the Solar Panel is vulnerable to a Stored Cross-Site Scripting (XSS) attack on /file.bootloader.upload.html. The application fails to sanitize the parameter filename, in a POST request to /file.bootloader.upload.html for a system update, thus allowing one to inject HTML and/or JavaScript on the page that will then be processed and stored by the application. Any subsequent requests to pages that retrieve the malicious content will automatically exploit the vulnerability on the victim's browser. This also happens because the tag is loaded in the function innerHTML in the page HTML."
},
{
"lang": "es",
"value": "En Kostal PIKO 1.5-1 MP plus HMI OEM p 1.0.1, la aplicación web para el panel solar es vulnerable a un ataque de Cross-Site Scripting Almacenado (XSS) en /file.bootloader.upload.html. La aplicación no puede sanitizar el nombre del archivo del parámetro, en una solicitud POST a /file.bootloader.upload.html para una actualización del sistema, lo que permite inyectar HTML y/o JavaScript en la página que luego será procesada y almacenada por la aplicación. Cualquier solicitud posterior a páginas que recuperen contenido malicioso explotará automáticamente la vulnerabilidad en el navegador de la víctima. Esto también sucede porque la etiqueta se carga en la función InnerHTML en la página HTML."
}
],
"lastModified": "2026-06-17T05:05:42.043",
"sourceIdentifier": "cve@mitre.org"
}