« Volver al listado

CVE-2022-4280

Estado: ModificadaAlta (7.5)—

A vulnerability, which was classified as problematic, has been found in Dot Tech Smart Campus System. Affected by this issue is some unknown functionality of the file /services/Card/findUser. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-214778 is the identifier assigned to this vulnerability.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-4280",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-4280",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-14T16:55:51.450601Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "vendor": "Dot Tech",
          "product": "Smart Campus System",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-12-03T18:15:10.243",
  "references": [
    {
      "url": "https://github.com/Peanut886/Vulnerability/blob/main/Information%20leakage%20vulnerability%20exists%20in%20findUser%2C%20a%20smart%20campus%20system%20developed%20by%20Dot%20Tech.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?id.214778",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://github.com/Peanut886/Vulnerability/blob/main/Information%20leakage%20vulnerability%20exists%20in%20findUser%2C%20a%20smart%20campus%20system%20developed%20by%20Dot%20Tech.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?id.214778",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-266"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability, which was classified as problematic, has been found in Dot Tech Smart Campus System. Affected by this issue is some unknown functionality of the file /services/Card/findUser. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-214778 is the identifier assigned to this vulnerability."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Dot Tech Smart Campus System y clasificada como problemática. Una función desconocida del archivo /services/Card/findUser es afectada por esta vulnerabilidad. La manipulación conduce a la divulgación de información. El ataque puede lanzarse de forma remota. La explotación ha sido divulgada al público y puede utilizarse. VDB-214778 es el identificador asignado a esta vulnerabilidad."
    }
  ],
  "lastModified": "2026-06-17T05:20:28.550",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dottech:smart_campus_system:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2DAC785C-18A2-4AB7-ADAE-7FD591BF00DC"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cna@vuldb.com"
}