« Volver al listado

CVE-2022-41851

Estado: ModificadaAlta (7.8)—

A vulnerability has been identified in JTTK (All versions < V11.1.1.0), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973)

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-41851",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-41851",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-20T14:13:03.902435Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "JTTK",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V11.1.1.0"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap V2022.1",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2022.1.3"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap V2022.2",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V2022.2.2"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-10-11T11:15:11.120",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-611756.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-611756.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in JTTK (All versions < V11.1.1.0), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en JTTK (Todas las versiones anteriores a V11.1.1.0), Simcenter Femap V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap V2022.2 (Todas las versiones anteriores a V2022.2.2). La biblioteca JTTK es susceptible a una vulnerabilidad de referencia de puntero no inicializada mientras analiza archivos JT especialmente diseñados. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. (ZDI-CAN-16973)"
    }
  ],
  "lastModified": "2026-06-17T05:03:55.897",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8E5FA782-E074-4406-ACA6-788DD24327C7",
              "versionEndExcluding": "11.1.1.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5CC6B707-5527-4A4F-BA46-C2EE6CCF8E56",
              "versionEndExcluding": "2022.1.3",
              "versionStartIncluding": "2022.1.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "98BF38F3-E62A-4913-A300-EF7F3001BC64",
              "versionEndExcluding": "2022.2.2",
              "versionStartIncluding": "2022.2.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}