« Volver al listado

CVE-2022-41669

Estado: ModificadaAlta (7.8)—

A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-41669",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-41669",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-02T18:27:46.914216Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "EcoStruxure Operator Terminal Expert",
          "versions": [
            {
              "status": "affected",
              "version": "V3.3",
              "versionType": "custom",
              "lessThanOrEqual": "Hotfix 1"
            }
          ]
        },
        {
          "vendor": "Schneider Electric",
          "product": "Pro-face BLUE",
          "versions": [
            {
              "status": "affected",
              "version": "V3.3",
              "versionType": "custom",
              "lessThanOrEqual": "Hotfix 1"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-11-04T13:15:11.250",
  "references": [
    {
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-284-01/",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-284-01/",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-347"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior)."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad CWE-347: Verificación Inadecuada de Firma Criptográfica en el componente SGIUtility que permite a adversarios con privilegios de usuario local cargar una DLL maliciosa que podría resultar en la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior)."
    }
  ],
  "lastModified": "2026-06-17T05:03:36.323",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5705916B-E189-4314-AD32-C8D42991DFA2",
              "versionEndExcluding": "3.3"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A6EAEC62-F689-43A2-8EDB-68867661ED92"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hotfix1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "54A2C97D-9FE0-4E01-B9BE-D5508CFEEB5A"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "297C4149-AA1F-4033-BD74-0FB908783399",
              "versionEndExcluding": "3.3"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:3.3:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FB229476-7E0C-46ED-817D-C9A72250CC5D"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hotfix1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C893D88A-656A-4748-841C-5851D34E9C69"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}