« Volver al listado

CVE-2022-40846

Estado: AnalizadaMedia (4.8)—

In Tenda AC1200 Router model W15Ev2 V15.11.0.10(1576), a Stored Cross Site Scripting (XSS) vulnerability exists allowing an attacker to execute JavaScript code via the applications stored hostname.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-40846",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-40846",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-30T14:48:20.240654Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 4.8,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 1.7
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 4.8,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 1.7
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-11-15T03:15:14.713",
  "references": [
    {
      "url": "https://boschko.ca/tenda_ac1200_router/",
      "tags": [
        "Exploit",
        "Technical Description",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://boschko.ca/tenda_ac1200_router/",
      "tags": [
        "Exploit",
        "Technical Description",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Tenda AC1200 Router model W15Ev2 V15.11.0.10(1576), a Stored Cross Site Scripting (XSS) vulnerability exists allowing an attacker to execute JavaScript code via the applications stored hostname."
    },
    {
      "lang": "es",
      "value": "En Tenda AC1200 Router modelo W15Ev2 V15.11.0.10(1576), existe una vulnerabilidad de Cross-Site Scripting (XSS) Almacenado que permite a un atacante ejecutar código JavaScript a través del nombre de host almacenado de la aplicación."
    }
  ],
  "lastModified": "2026-06-17T05:02:07.287",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:w15e_firmware:15.11.0.10\\(1576\\):*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "03AB5835-92BD-42C1-ADA6-654161BFDFC4"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:w15e:2.0:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4EF5F7DF-4B18-4AE3-B8BD-B051761291CE"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}