« Back to list

CVE-2022-40691

Status: ModifiedMedium (5.3)—

An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (2)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2022-40691",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-40691",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-01T17:20:38.057437Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "talos-cna@cisco.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "talos-cna@cisco.com",
      "affectedData": [
        {
          "vendor": "Moxa",
          "product": "SDS-3008 Series Industrial Ethernet Switch",
          "versions": [
            {
              "status": "affected",
              "version": "2.1"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "moxa",
          "product": "sds-3008_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "2.1"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "moxa",
          "product": "sds-3008-t_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "2.1"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-02-07T17:15:10.330",
  "references": [
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1621",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "talos-cna@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability."
    }
  ],
  "lastModified": "2026-06-17T05:01:50.870",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0",
              "versionEndIncluding": "2.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726",
              "versionEndIncluding": "2.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com"
}