CVE-2022-39065
Estado: ModificadaMedia (6.5)—
A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.41%
- Percentil entre todas las CVEs puntuadas: 33
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-241
- NVD-CWE-Other
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-39065",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-39065",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-15T13:44:59.292209Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "disclosure@synopsys.com",
"affectedData": [
{
"vendor": "Ikea",
"product": "TRÅDFRI gateway system",
"versions": [
{
"status": "affected",
"version": "< 1.19.26"
}
]
}
]
}
],
"published": "2022-10-14T16:15:19.243",
"references": [
{
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/",
"tags": [
"Third Party Advisory"
],
"source": "disclosure@synopsys.com"
},
{
"url": "https://www.synopsys.com/blogs/software-security/cyrc-advisory-ikea-tradfri-smart-lighting-gateway/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@synopsys.com",
"description": [
{
"lang": "en",
"value": "CWE-241"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI gateway unresponsive, such that connected lighting cannot be controlled with the IKEA Home Smart app and TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score: 6.5 Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
},
{
"lang": "es",
"value": "Una única trama IEEE 802.15.4 (Zigbee) malformada hace que la pasarela TRÅDFRI no responda, de modo que la iluminación conectada no puede controlarse con la aplicación IKEA Home Smart y el mando a distancia TRÅDFRI. La trama Zigbee malformada es un mensaje de difusión no autenticado, lo que significa que todos los dispositivos vulnerables dentro del rango de radio están afectados. CVSS 3.1, Puntuación Base 6.5, Vector CVSS: 3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"lastModified": "2026-06-17T04:57:31.900",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ikea:tradfri_gateway_e1526_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CCEFB34F-7A58-4FFC-A8A2-42A369D271E3",
"versionEndExcluding": "1.19.26"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ikea:tradfri_gateway_e1526:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FE61F613-9822-4B7D-BB22-15F6B0107DFB"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "disclosure@synopsys.com"
}