« Volver al listado

CVE-2022-37680

Estado: ModificadaAlta (7.5)—

An improper authentication for critical function issue in Hitachi Kokusai Electric Network products for monitoring system (Camera, Decoder and Encoder) and bellow allows attckers to remotely reboot the device via a crafted POST request to the endpoint /ptipupgrade.cgi. Security information ID hitachi-sec-2022-001 contains fixes for the issue.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-37680",
  "cveTags": [],
  "metrics": {
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "hirt@hitachi.co.jp",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "hirt@hitachi.co.jp",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "unknown",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-08-29T23:15:08.687",
  "references": [
    {
      "url": "https://gist.github.com/Nwqda/5efea18c9142c6a966d85c6be2c0c2b5",
      "source": "hirt@hitachi.co.jp"
    },
    {
      "url": "https://www.hitachi-kokusai.co.jp/global/en/products/info/vulnerable/hitachi-sec-2022-001/index.html",
      "source": "hirt@hitachi.co.jp"
    },
    {
      "url": "https://gist.github.com/Nwqda/5efea18c9142c6a966d85c6be2c0c2b5",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.hitachi-kokusai.co.jp/global/en/products/info/vulnerable/hitachi-sec-2022-001/index.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An improper authentication for critical function issue in Hitachi Kokusai Electric Network products for monitoring system (Camera, Decoder and Encoder) and bellow allows attckers to remotely reboot the device via a crafted POST request to the endpoint /ptipupgrade.cgi. Security information ID hitachi-sec-2022-001 contains fixes for the issue."
    },
    {
      "lang": "es",
      "value": "Un problema de autenticación inadecuada para una función crítica en los productos de red de Hitachi Kokusai Electric para el sistema de supervisión (cámara, decodificador y codificador) y siguientes permite a los atacantes reiniciar el dispositivo de forma remota a través de una solicitud POST manipulada en el punto final /ptipupgrade.cgi. La información de seguridad ID hitachi-sec-2022-001 contiene correcciones para el problema"
    }
  ],
  "lastModified": "2026-06-17T04:55:10.507",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hitachi:hc-ip9100hd_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EC7F4AF8-2464-4A33-935D-5F43C23DAE79",
              "versionEndIncluding": "1.07"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hitachi:hc-ip9100hd:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2B1BBA4B-17AA-48D8-8CE3-70E29BFB35AD"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "hirt@hitachi.co.jp"
}