CVE-2022-34754
Status: ModifiedMedium (6.8)—
A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior)
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Base score: 6.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.30%
- Percentile among all scored CVEs: 21
- Score date: 10/7/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (2)
CWEs
- CWE-269
References
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-03_Acti9_PowerTag_Link_C_Security_Notification.pdf
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-03_Acti9_PowerTag_Link_C_Security_Notification.pdf
Raw JSON (NVD)
Show
{
"id": "CVE-2022-34754",
"cveTags": [],
"metrics": {
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Acti9 PowerTag Link C",
"versions": [
{
"status": "affected",
"version": "A9XELC10-A",
"lessThan": "V1.7.5",
"versionType": "custom"
},
{
"status": "affected",
"version": "A9XELC10-B",
"lessThan": "V2.12.0",
"versionType": "custom"
}
]
}
]
}
],
"published": "2022-07-13T21:15:08.227",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-03_Acti9_PowerTag_Link_C_Security_Notification.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-193-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-03_Acti9_PowerTag_Link_C_Security_Notification.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior)"
},
{
"lang": "es",
"value": "Una CWE-269: Se presenta una vulnerabilidad de Administración de Privilegios Inapropiada que podría permitir una funcionalidad elevada cuando se adivinan las credenciales. Productos afectados: Acti9 PowerTag Link C (A9XELC10-A) (versiones V1.7.5 y anteriores), Acti9 PowerTag Link C (A9XELC10-B) (versiones V2.12.0 y anteriores)"
}
],
"lastModified": "2026-06-17T04:50:51.997",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-a\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "427BD8F4-7B5B-44D2-8CB0-975114D52BB6",
"versionEndIncluding": "1.7.5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-a\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A13046EC-90A1-4EE2-AA92-3A6BA721FDDD"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-b\\)_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "64F28B16-BCCD-44D4-9EF2-A5138B1DC152",
"versionEndIncluding": "2.12.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:acti9_powertag_link_c_\\(a9xelc10-b\\):-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E58E9CC3-6865-4E11-91E1-99C0EFD0EE3F"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}