CVE-2022-34447

Estado: ModificadaAlta (7.2)—

PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-34447",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-34447",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-24T14:32:16.499576Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "PowerPath Management Appliance",
          "versions": [
            {
              "status": "affected",
              "version": "3.3, 3.2*, 3.1, 3.0*"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-02-11T01:23:24.903",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/000205404",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/000205404",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nPowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains OS Command Injection vulnerability. An authenticated remote attacker with administrative privileges could potentially exploit the issue and execute commands on the system as the root user.\n\n\n\n\n\n"
    }
  ],
  "lastModified": "2026-06-17T04:50:22.483",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "02C04418-5B17-4B1E-A547-88AB9D54437F"
            },
            {
              "criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FC22B1B0-E9A4-44F7-BAA3-7F3F592448FE"
            },
            {
              "criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D92273A9-3C81-4082-9550-DC1497AEDF39"
            },
            {
              "criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8AD7DBFF-1187-4F94-A3A4-95D52E6B3DC4"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}