« Volver al listado

CVE-2022-34446

Estado: ModificadaAlta (8.1)—

PowerPath Management Appliance with versions 3.3 & 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-34446",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-34446",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-26T15:14:22.136061Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "PowerPath Management Appliance",
          "versions": [
            {
              "status": "affected",
              "version": "3.3, 3.2*"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-02-11T01:23:24.780",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/000205404",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/000205404",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-285"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nPowerPath Management Appliance with versions 3.3 & 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.\n\n\n\n\n\n"
    }
  ],
  "lastModified": "2026-06-17T04:50:22.373",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D92273A9-3C81-4082-9550-DC1497AEDF39"
            },
            {
              "criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8AD7DBFF-1187-4F94-A3A4-95D52E6B3DC4"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}