Estado: AplazadaMedia (6.3)—

An issue was discovered on certain Nuki Home Solutions devices. There is a buffer overflow over the encrypted token parsing logic in the HTTP service that allows remote code execution. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-32502",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-32502",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-06-18T15:31:08.771490Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 3.4,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:nuki:nuki_smart_lock:2.0:*:*:*:*:*:*:*"
          ],
          "vendor": "nuki",
          "product": "nuki_smart_lock",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "1.22.0",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.13.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-05-14T10:43:40.783",
  "references": [
    {
      "url": "https://latesthackingnews.com/2022/07/28/multiple-security-flaws-found-in-nuki-smart-locks/",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://nuki.io/en/security-updates/",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://research.nccgroup.com/2022/07/25/technical-advisory-multiple-vulnerabilities-in-nuki-smart-locks-cve-2022-32509-cve-2022-32504-cve-2022-32502-cve-2022-32507-cve-2022-32503-cve-2022-32510-cve-2022-32506-cve-2022-32508-cve-2/",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.hackread.com/nuki-smart-locks-vulnerabilities-plethora-attack-options/",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://latesthackingnews.com/2022/07/28/multiple-security-flaws-found-in-nuki-smart-locks/",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://nuki.io/en/security-updates/",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://research.nccgroup.com/2022/07/25/technical-advisory-multiple-vulnerabilities-in-nuki-smart-locks-cve-2022-32509-cve-2022-32504-cve-2022-32502-cve-2022-32507-cve-2022-32503-cve-2022-32510-cve-2022-32506-cve-2022-32508-cve-2/",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.hackread.com/nuki-smart-locks-vulnerabilities-plethora-attack-options/",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on certain Nuki Home Solutions devices. There is a buffer overflow over the encrypted token parsing logic in the HTTP service that allows remote code execution. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en determinados dispositivos de Nuki Home Solutions. Hay un desbordamiento del búfer sobre la lógica de análisis del token cifrado en el servicio HTTP que permite la ejecución remota de código. Esto afecta a Nuki Bridge v1 anterior a 1.22.0 y v2 anterior a 2.13.2."
    }
  ],
  "lastModified": "2026-06-17T04:47:25.497",
  "sourceIdentifier": "cve@mitre.org"
}