« Volver al listado

CVE-2022-32384

Estado: ModificadaAlta (8.8)—

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the security_5g parameter in the function formWifiBasicSet.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-32384",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.8,
          "accessVector": "ADJACENT_NETWORK",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.5,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-07-01T21:15:08.320",
  "references": [
    {
      "url": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view?usp=sharing",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://drive.google.com/file/d/16hshiCHS8j3YaFPkQD3xajVuwu_QVBe3/view?usp=sharing",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the security_5g parameter in the function formWifiBasicSet."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC23 versión v16.03.07.44, contiene un desbordamiento de pila por medio del parámetro security_5g en la función formWifiBasicSet"
    }
  ],
  "lastModified": "2026-07-09T01:17:31.533",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tendacn:ac23_ac2100_firmware:16.03.07.44:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1874FFA4-4C7D-43DC-8C4F-62386704EA37"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tendacn:ac23_ac2100:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "91036786-3497-4A99-8081-E9A97BE49551"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}