« Volver al listado

CVE-2022-2967

Estado: ModificadaAlta (7.5)—

Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-2967",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-2967",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-16T20:32:48.380253Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "ics-cert@hq.dhs.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.6
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "Prosys OPC",
          "product": "UA Simulation Server",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "5.3.0-64",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Prosys OPC",
          "product": "UA Modbus Server",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.4.18-5"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-01-03T22:15:11.757",
  "references": [
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-01",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.prosysopc.com/blog/#Security",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-01",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.prosysopc.com/blog/#Security",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Prosys OPC UA Simulation Server version prior to v5.3.0-64 and UA Modbus Server versions 1.4.18-5 and prior do not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data."
    },
    {
      "lang": "es",
      "value": "La versión del servidor de simulación Prosys OPC UA anterior a la v5.3.0-64 y las versiones del UA Modbus Server 1.4.18-5 y anteriores no protegen suficientemente las credenciales, lo que podría permitir a un atacante obtener credenciales de usuario y acceder a los datos del sistema."
    }
  ],
  "lastModified": "2026-06-17T04:42:54.103",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:prosysopc:ua_modbus_server:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DBD45F09-929C-4DFC-844D-3AC4E00F4F66",
              "versionEndExcluding": "1.4.20"
            },
            {
              "criteria": "cpe:2.3:a:prosysopc:ua_simulation_server:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9C7B35D9-620E-45A2-8717-91ACD9FFB3FD",
              "versionEndExcluding": "5.4.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}