CVE-2022-29059
An improper neutralization of special elements used in an SQL command ('SQL Injection') vulnerability [CWE-89] in FortiWeb version 7.0.1 and below, 6.4.2 and below, 6.3.20 and below, 6.2.7 and below may allow a privileged attacker to execute SQL commands over the log database via specifically crafted strings parameters.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.41%
- Percentil entre todas las CVEs puntuadas: 33
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement90 % - Impacto principal
T1005Data from Local Systemcollection85 % - Impacto secundario
T1565.001Stored Data Manipulationimpact80 %
SQL injection en FortiWeb (CWE-89) requiere privilegios altos (PR:H) en red, acceso a base de datos de logs. Permite lectura (T1005) y manipulación (T1565.001) de datos persistidos.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-29059",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-29059",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-14T17:49:57.286454Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@fortinet.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 2.7,
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 1.2
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "psirt@fortinet.com",
"affectedData": [
{
"vendor": "Fortinet",
"product": "FortiWeb",
"versions": [
{
"status": "affected",
"version": "7.0.0",
"versionType": "semver",
"lessThanOrEqual": "7.0.1"
},
{
"status": "affected",
"version": "6.4.0",
"versionType": "semver",
"lessThanOrEqual": "6.4.3"
},
{
"status": "affected",
"version": "6.3.0",
"versionType": "semver",
"lessThanOrEqual": "6.3.23"
},
{
"status": "affected",
"version": "6.2.3",
"versionType": "semver",
"lessThanOrEqual": "6.2.8"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-03-14T16:15:27.027",
"references": [
{
"url": "https://fortiguard.com/psirt/FG-IR-22-140",
"tags": [
"Vendor Advisory"
],
"source": "psirt@fortinet.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@fortinet.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper neutralization of special elements used in an SQL command ('SQL Injection') vulnerability [CWE-89] in FortiWeb version 7.0.1 and below, 6.4.2 and below, 6.3.20 and below, 6.2.7 and below may allow a privileged attacker to execute SQL commands over the log database via specifically crafted strings parameters."
},
{
"lang": "es",
"value": "Una vulnerabilidad de neutralización incorrecta de elementos especiales utilizados en un comando SQL ('SQL Injection') [CWE-89] en FortiWeb versión 7.0.1 y anteriores, 6.4.2 y anteriores, 6.3.20 y anteriores, 6.2.7 y anteriores puede permitir que un atacante privilegiado ejecute comandos SQL sobre la base de datos de registros a través de parámetros de cadenas específicamente manipulados."
}
],
"lastModified": "2026-06-17T04:39:31.473",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6BEC9155-F85D-4E82-903C-001822686BE0",
"versionEndIncluding": "6.2.7",
"versionStartIncluding": "6.2.3"
},
{
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "35014331-8ACF-44BF-82B7-D11E7A8BE750",
"versionEndIncluding": "6.3.18",
"versionStartIncluding": "6.3.0"
},
{
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F6B93ABE-8620-4253-83C0-3D2228D20118",
"versionEndIncluding": "6.4.2",
"versionStartIncluding": "6.4.0"
},
{
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9054E8B0-2CF0-4DD3-8D5A-34C399F7C20D",
"versionEndExcluding": "7.0.2",
"versionStartIncluding": "7.0.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "psirt@fortinet.com"
}