« Volver al listado

CVE-2022-28645

Estado: ModificadaMedia (5.5)—

This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.02.34. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-16470.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-28645",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-28645",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-02-18T20:07:13.176184Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "zdi-disclosures@trendmicro.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 3.3,
          "attackVector": "LOCAL",
          "baseSeverity": "LOW",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 1.8
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "affectedData": [
        {
          "vendor": "Bentley",
          "product": "MicroStation CONNECT",
          "versions": [
            {
              "status": "affected",
              "version": "10.16.02.34"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-03-29T19:15:10.907",
  "references": [
    {
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0004",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-610/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    },
    {
      "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0004",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-610/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "zdi-disclosures@trendmicro.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley MicroStation CONNECT 10.16.02.34. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. Crafted data in a DGN file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-16470."
    }
  ],
  "lastModified": "2026-06-17T04:38:46.400",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bentley:microstation:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E8074E06-8E40-46EB-8523-476C2D5532AA",
              "versionEndExcluding": "10.16.03"
            },
            {
              "criteria": "cpe:2.3:a:bentley:view:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8C8BCADD-027D-487D-AE7E-047D2B467AD6",
              "versionEndExcluding": "10.16.03"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com"
}