« Volver al listado

CVE-2022-28556

Estado: ModificadaAlta (7.5)—

Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-28556",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-05-04T16:15:08.647",
  "references": [
    {
      "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/doudoudedi/TendaAC15_vul/blob/main/TendaAC15-vul.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971"
    },
    {
      "lang": "es",
      "value": "Tenda AC15 versión US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin, es vulnerable a un desbordamiento del búfer. La vulnerabilidad de desbordamiento de pila se encuentra en la interfaz /goform/setpptpservercfg de la web. Los datos post enviados startip y endip son copiados a la pila usando la función sanf, resultando en un desbordamiento de pila. Del mismo modo, esta vulnerabilidad puede usarse junto con CVE-2021-44971"
    }
  ],
  "lastModified": "2026-06-17T04:38:38.970",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi_tde01:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B9C2B371-287E-4062-BC68-EFBE4D5DC908"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}