CVE-2022-2741
Estado: ModificadaAlta (7.5)—
The denial-of-service can be triggered by transmitting a carefully crafted CAN frame on the same CAN network as the vulnerable node. The frame must have a CAN ID matching an installed filter in the vulnerable node (this can easily be guessed based on CAN traffic analyses). The frame must contain the opposite RTR bit as what the filter installed in the vulnerable node contains (if the filter matches RTR frames, the frame must be a data frame or vice versa).
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.64%
- Percentil entre todas las CVEs puntuadas: 49
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-400
- CWE-400
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-2741",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-2741",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-05T14:05:55.970352Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "vulnerabilities@zephyrproject.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 4.2,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "vulnerabilities@zephyrproject.org",
"affectedData": [
{
"vendor": "zephyrproject-rtos",
"product": "zephyr",
"versions": [
{
"status": "affected",
"version": "unspecified",
"versionType": "custom",
"lessThanOrEqual": "v3.1"
}
]
}
]
}
],
"published": "2022-10-31T18:15:13.870",
"references": [
{
"url": "https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-hx5v-j59q-c3j8",
"tags": [
"Patch",
"Third Party Advisory"
],
"source": "vulnerabilities@zephyrproject.org"
},
{
"url": "https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-hx5v-j59q-c3j8",
"tags": [
"Patch",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "vulnerabilities@zephyrproject.org",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The denial-of-service can be triggered by transmitting a carefully crafted CAN frame on the same CAN network as the vulnerable node. The frame must have a CAN ID matching an installed filter in the vulnerable node (this can easily be guessed based on CAN traffic analyses). The frame must contain the opposite RTR bit as what the filter installed in the vulnerable node contains (if the filter matches RTR frames, the frame must be a data frame or vice versa)."
},
{
"lang": "es",
"value": "La denegación de servicio puede activarse transmitiendo un frame CAN cuidadosamente manipulada en la misma red CAN que el nodo vulnerable. El frame debe tener una ID CAN que coincida con un filtro instalado en el nodo vulnerable (esto se puede adivinar fácilmente basándose en los análisis de tráfico CAN). El frame debe contener el bit RTR opuesto al que contiene el filtro instalado en el nodo vulnerable (si el filtro coincide con frame RTR, el frame debe ser un frame de datos o viceversa)."
}
],
"lastModified": "2026-06-17T04:42:29.470",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:zephyrproject:zephyr:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0C7142ED-492C-44F4-88A4-2BB2E455C59A",
"versionEndIncluding": "3.1.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "vulnerabilities@zephyrproject.org"
}