A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph:

Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:

Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:

Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:

Versions 2.2.0 and prior.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (9)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-26388",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-26388",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-02-07T18:50:50.198188Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productsecurity@baxter.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.4,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.5,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "productsecurity@baxter.com",
      "affectedData": [
        {
          "vendor": "Welch Allyn",
          "product": "ELI 380 Resting Electrocardiograph",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "2.6.0"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Welch Allyn",
          "product": "ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "2.3.1"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Welch Allyn",
          "product": "ELI 250c/BUR 250c Resting Electrocardiograph",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "2.1.2"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Welch Allyn",
          "product": "ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "2.2.0"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-02-07T17:15:21.960",
  "references": [
    {
      "url": "https://hillrom.com/en/responsible-disclosures/",
      "source": "productsecurity@baxter.com"
    },
    {
      "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01",
      "source": "productsecurity@baxter.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productsecurity@baxter.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: \n\nVersions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\nVersions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:\n\nVersions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\nVersions 2.2.0 and prior."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en el uso de contraseñas codificadas de forma rígida puede permitir el abuso de la autenticación. Este problema afecta al electrocardiógrafo en reposo ELI 380: versiones 2.6.0 y anteriores; al electrocardiógrafo en reposo ELI 280/BUR280/MLBUR 280: versiones 2.3.1 y anteriores; al electrocardiógrafo en reposo ELI 250c/BUR 250c: versiones 2.1.2 y anteriores; al electrocardiógrafo en reposo ELI 150c/BUR 150c/MLBUR 150c: versiones 2.2.0 y anteriores."
    }
  ],
  "lastModified": "2026-06-17T04:35:08.587",
  "sourceIdentifier": "productsecurity@baxter.com"
}