CVE-2022-26077
Estado: ModificadaAlta (7.5)—
A cleartext transmission of sensitive information vulnerability exists in the OAS Engine configuration communications functionality of Open Automation Software OAS Platform V16.00.0112. A targeted network sniffing attack can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.14%
- Percentil entre todas las CVEs puntuadas: 65
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-319
- CWE-319
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-26077",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-26077",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-04-15T18:18:55.327468Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "Open Automation Software",
"product": "OAS Platform",
"versions": [
{
"status": "affected",
"version": "V16.00.0112"
}
]
}
]
}
],
"published": "2022-05-25T21:15:08.097",
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1490",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1490",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cleartext transmission of sensitive information vulnerability exists in the OAS Engine configuration communications functionality of Open Automation Software OAS Platform V16.00.0112. A targeted network sniffing attack can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de transmisión de texto sin cifrar de información confidencial en la funcionalidad OAS Engine configuration communications de Open Automation Software OAS Platform versión V16.00.0112. Un ataque de sniffing de red dirigido puede conllevar a una divulgación de información confidencial. Un atacante puede olfatear el tráfico de red para desencadenar esta vulnerabilidad"
}
],
"lastModified": "2026-06-17T04:34:38.863",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:openautomationsoftware:oas_platform:16.00.0112:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "53E04F42-0257-46EF-B70E-BFEEF713F2A5"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}