« Volver al listado

CVE-2022-26067

Estado: ModificadaAlta (7.5)—

An information disclosure vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to arbitrary file read. An attacker can send a sequence of requests to trigger this vulnerability.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2022-26067",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-26067",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-15T18:18:00.743542Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "talos-cna@cisco.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "talos-cna@cisco.com",
      "affectedData": [
        {
          "vendor": "Open Automation Software",
          "product": "OAS Platform",
          "versions": [
            {
              "status": "affected",
              "version": "V16.00.0112"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-05-25T21:15:08.047",
  "references": [
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1492",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1492",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "talos-cna@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An information disclosure vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to arbitrary file read. An attacker can send a sequence of requests to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de divulgación de información en la funcionalidad OAS Engine SecureTransferFiles de Open Automation Software OAS Platform versión V16.00.0112. Una serie de peticiones de red especialmente diseñadas puede conllevar a una lectura arbitraria de archivos. Un atacante puede enviar una secuencia de peticiones para desencadenar esta vulnerabilidad"
    }
  ],
  "lastModified": "2026-06-17T04:34:37.753",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:openautomationsoftware:oas_platform:16.00.0112:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "53E04F42-0257-46EF-B70E-BFEEF713F2A5"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com"
}