CVE-2022-24436
Status: ModifiedMedium (6.5)—
Observable behavioral in power management throttling for some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via network access.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
- Base score: 6.5
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 12%
- Percentile among all scored CVEs: 96
- Score date: 10/10/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-203
- CWE-203
References
Raw JSON (NVD)
Show
{
"id": "CVE-2022-24436",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-24436",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-04-23T13:20:33.956066Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"authentication": "SINGLE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Intel(R) Processors",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
]
}
],
"published": "2022-06-15T21:15:09.293",
"references": [
{
"url": "https://security.netapp.com/advisory/ntap-20220624-0007/",
"tags": [
"Third Party Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00698.html",
"tags": [
"Vendor Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://security.netapp.com/advisory/ntap-20220624-0007/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00698.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-203"
}
]
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-203"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Observable behavioral in power management throttling for some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via network access."
},
{
"lang": "es",
"value": "Un comportamiento observable en la regulación de la administración de la energía para algunos procesadores Intel(R) puede permitir que un usuario autenticado permita potencialmente una divulgación de información por medio del acceso a la red"
}
],
"lastModified": "2026-06-17T04:31:50.537",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:*:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "89CBE93C-BB36-4F26-9F73-554C9BB8E131"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secure@intel.com"
}