CVE-2022-24353
Status: ModifiedHigh (8.8)—
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link AC1750 1.1.4 Build 20211022 rel.59103(5553) routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the NetUSB.ko module. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the root user. Was ZDI-CAN-15769.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Base score: 8.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.74%
- Percentile among all scored CVEs: 53
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-125
References
Raw JSON (NVD)
Show
{
"id": "CVE-2022-24353",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-24353",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-02-19T15:41:57.283564Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "TP-Link",
"product": "AC1750",
"versions": [
{
"status": "affected",
"version": "1.1.4 Build 20211022 rel.59103(5553)"
}
]
}
]
}
],
"published": "2023-03-28T19:15:10.653",
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-263/",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-263/",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link AC1750 1.1.4 Build 20211022 rel.59103(5553) routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the NetUSB.ko module. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the root user. Was ZDI-CAN-15769."
}
],
"lastModified": "2026-06-17T04:31:40.990",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:ac1750_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DFD9B8CC-B355-41BE-8139-C84044008DEF",
"versionEndExcluding": "211210"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:ac1750:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D9017433-E653-4983-B0C4-B5AB9AF67AE4"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}