CVE-2022-22515
Estado: ModificadaAlta (8.1)—
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.11%
- Percentil entre todas las CVEs puntuadas: 65
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (18)
Codesys — Control FOR Beaglebone SLCodesys — Control FOR Beckhoff Cx9020Codesys — Control FOR Empc-a/imx6 SLCodesys — Control FOR Iot2000 SLCodesys — Control FOR Linux SLCodesys — Control FOR Pfc100 SLCodesys — Control FOR Pfc200 SLCodesys — Control FOR Plcnext SLCodesys — Control FOR Raspberry PI SLCodesys — Control FOR Wago Touch Panels 600 SLCodesys — Control RTE SLCodesys — Control RTE SL (for Beckhoff CX)Codesys — Control Runtime System ToolkitCodesys — Control WIN SLCodesys — Development SystemCodesys — Embedded Target Visu ToolkitCodesys — HMI SLCodesys — Remote Target Visu Toolkit
CWE
- CWE-668
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-22515",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:N",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 4.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "info@cert.vde.com",
"affectedData": [
{
"vendor": "CODESYS",
"product": "CODESYS Control RTE (SL)",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control Win (SL)",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS HMI (SL)",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Development System V3",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control Runtime System Toolkit",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Embedded Target Visu Toolkit",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Remote Target Visu Toolkit",
"versions": [
{
"status": "affected",
"version": "V3",
"lessThan": "V3.5.17.40",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for BeagleBone SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for Beckhoff CX9020 SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for IOT2000 SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for Linux SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for PFC100 SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for PFC200 SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for PLCnext SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for Raspberry Pi SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
},
{
"vendor": "CODESYS",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"versions": [
{
"status": "affected",
"version": "V4",
"lessThan": "V4.5.0.0",
"versionType": "custom"
}
]
}
]
}
],
"published": "2022-04-07T19:15:08.187",
"references": [
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download=",
"tags": [
"Vendor Advisory"
],
"source": "info@cert.vde.com"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download=",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"description": [
{
"lang": "en",
"value": "CWE-668"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
},
{
"lang": "es",
"value": "Un atacante remoto y autentificado podría utilizar el programa de control del sistema de tiempo de ejecución CODESYS Control para utilizar la vulnerabilidad con el fin de leer y modificar el/los archivo/s de configuración de los productos afectados"
}
],
"lastModified": "2026-06-17T04:28:30.573",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5C0588BE-2046-48F8-95E9-338FB009E2FA",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_beckhoff_cx9020:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "45FF3C0B-9043-4E82-A8F3-95CB79D8DAA1",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4CB8984E-ED1F-4F52-B016-F08C0D085C64",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "412EBC80-0D9C-419F-9DC3-E2054A8B93B0",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AB585AB5-D0AC-46DC-9723-A0FEFBFB015C",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4F6E2A1D-0187-4C71-A87D-48B3EC3D99DD",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A78E493B-6D9E-4196-830C-24BCF25D3D44",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F66AAE46-CCF8-46D6-89AD-5A4461FCECE9",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9D5DE9D1-C334-452C-A64B-D74A48017B6D",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AB1C57CE-152A-44AE-98B8-39E310255C8E",
"versionEndExcluding": "4.5.0.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "01A94C91-B155-4A5A-9F0B-F7E04F3B23B5",
"versionEndExcluding": "3.5.18.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "95BC26CF-75EE-43A2-8A92-E877CAF612F3",
"versionEndExcluding": "3.5.18.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1D85A5BC-ADB6-40E4-9434-B57C99185BBA",
"versionEndExcluding": "3.5.18.0"
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AC013B85-98C0-4EF0-844C-4C75D1D237D9",
"versionEndExcluding": "3.5.18.0"
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "25737EE6-531E-4241-AA40-856388A2E333",
"versionEndExcluding": "3.5.18.0",
"versionStartIncluding": "3.0"
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E9F1B30B-6D52-40B1-ABD3-5164A76F5447",
"versionEndExcluding": "3.5.18.0"
},
{
"criteria": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "60E8930A-4C6C-41CE-8BA8-97332DC753FF",
"versionEndExcluding": "3.5.18.0"
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "879A9478-54E4-4B6E-A6DC-6DDE1C5E7745",
"versionEndExcluding": "3.5.18.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "info@cert.vde.com"
}