CVE-2022-1607
Estado: ModificadaAlta (8.8)—
Cross-Site Request Forgery (CSRF) vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant allows Cross Site Request Forgery.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-352
- CWE-352
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-1607",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-1607",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-11T15:54:53.693684Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.6,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 2.5,
"exploitabilityScore": 2.1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cybersecurity@ch.abb.com",
"affectedData": [
{
"vendor": "ABB",
"product": "Pulsar Plus System Controller NE843_S ",
"versions": [
{
"status": "affected",
"version": "comcode 150042936"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "ABB",
"product": "Infinity DC Power Plant",
"versions": [
{
"status": "affected",
"version": "H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-02-24T05:15:14.510",
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A6732&LanguageCode=en&DocumentPartId=&Action=Launch",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@ch.abb.com"
},
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A6732&LanguageCode=en&DocumentPartId=&Action=Launch",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant allows Cross Site Request Forgery.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415.\n\n"
}
],
"lastModified": "2026-06-17T04:22:46.690",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:abb:infinity_dc_power_plant:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "61279EF7-81F5-4044-9B54-9E263B4A4CBB",
"versionEndExcluding": "5.0.0"
},
{
"criteria": "cpe:2.3:a:abb:ne843_s:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "493D2774-FE8A-4709-A2B0-FA0A95DA3AC3",
"versionEndExcluding": "5.0.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com"
}