« Volver al listado

CVE-2021-46151

Estado: ModificadaAlta (7.8)—

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14754, ZDI-CAN-15082)

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-46151",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap V2020.2",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap V2021.1",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-02-09T16:15:14.393",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-291/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-292/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-609880.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-291/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-292/",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14754, ZDI-CAN-15082)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap versión V2020.2 (Todas las versiones), Simcenter Femap versión V2021.1 (Todas las versiones). La aplicación afectada contiene una escritura fuera de límites más allá del final de una estructura asignada mientras analiza archivos NEU especialmente diseñados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-14754, ZDI-CAN-15082)"
    }
  ],
  "lastModified": "2026-06-17T04:14:35.530",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2020.2:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "45178A46-1DB7-429A-8518-5D75669B4419"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2020.2:maintenance_pack1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F831F50A-896F-41D0-BEE2-8A5EFE0C5F0B"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2020.2:maintenance_pack2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7D862ED6-5E39-464B-ABC2-17846494BB52"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2020.2:maintenance_pack3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "751DB989-27BB-41EF-99D0-B00EC467AC79"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2021.1:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3DFF7E60-6EBE-410E-8C81-1E98A1C07AAD"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2021.1:maintenance_pack1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "19EEE97B-B2AD-4655-AE1C-5AD9717DE613"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2021.1:maintenance_pack2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DE6A20BD-A2D9-490D-A11F-862012BBF50C"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:2021.1:maintenance_pack3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D329656F-3939-4CB1-B2C8-28D10729030D"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}