« Back to list

CVE-2021-45600

Status: ModifiedHigh (7.2)—

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (4)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2021-45600",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cve@mitre.org",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 8.4,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 1.7
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-12-26T01:15:17.713",
  "references": [
    {
      "url": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR están afectados por una inyección de comandos por parte de un usuario autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12.\n"
    }
  ],
  "lastModified": "2026-06-17T04:13:44.550",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
              "versionEndExcluding": "4.6.3.6"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
              "versionEndExcluding": "3.2.17.12"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
              "versionEndExcluding": "3.2.17.12"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
              "versionEndExcluding": "3.2.17.12"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}