CVE-2021-45465
Estado: ModificadaAlta (7.8)—
A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.32%
- Percentil entre todas las CVEs puntuadas: 23
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-123
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-45465",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2021-45465",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-05-08T15:48:11.356596Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "syngo fastView",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-01-04T12:15:23.470",
"references": [
{
"url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-123"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en syngo fastView (todas las versiones). La aplicación afectada carece de una validación adecuada de los datos proporcionados por el usuario al analizar archivos BMP. Esto podría dar lugar a una condición de write-what-where y un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. (ZDI-CAN-15696)"
}
],
"lastModified": "2026-06-17T04:13:25.183",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens-healthineers:syngo_fastview:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B7D9A743-3BE4-4523-B34F-0C8461D3C63A"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}