Estado: ModificadaMedia (6.5)—

There is an information leak vulnerability in eCNS280_TD V100R005C10SPC650. The vulnerability is caused by improper log output management. An attacker with the ability to access the log file of device may lead to information disclosure.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-40007",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
          "authentication": "SINGLE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@huawei.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "eCNS280_TD",
          "versions": [
            {
              "status": "affected",
              "version": "V100R005C10SPC650"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-12-13T16:15:09.880",
  "references": [
    {
      "url": "https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20211208-01-informationleak-en",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "psirt@huawei.com"
    },
    {
      "url": "https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20211208-01-informationleak-en",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-116"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is an information leak vulnerability in eCNS280_TD V100R005C10SPC650. The vulnerability is caused by improper log output management. An attacker with the ability to access the log file of device may lead to information disclosure."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de filtrado de información en eCNS280_TD V100R005C10SPC650. La vulnerabilidad está causada por una administración inapropiada de la salida del registro. Un atacante con la capacidad de acceder al archivo de registro del dispositivo puede conllevar a una divulgación de información"
    }
  ],
  "lastModified": "2026-06-17T04:06:23.030",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:huawei:ecns280_td_firmware:v100r005c10spc650:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CEF25AB9-70FA-41EB-8F73-555826C493D9"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:huawei:ecns280_td:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "900FA565-05B8-41E9-BE02-9BC4E14A28F9"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "psirt@huawei.com"
}