« Volver al listado

CVE-2021-38399

Estado: ModificadaAlta (7.5)—

Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to relative path traversal, which may allow an attacker access to unauthorized files and directories.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (4)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-38399",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2021-38399",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-16T15:53:50.707446Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "ics-cert@hq.dhs.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "Honeywell",
          "product": "Experion PKS",
          "versions": [
            {
              "status": "affected",
              "version": "C200"
            },
            {
              "status": "affected",
              "version": "C200E"
            },
            {
              "status": "affected",
              "version": "C300"
            },
            {
              "status": "affected",
              "version": "ACE controllers"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-10-28T02:15:17.040",
  "references": [
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-278-04",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.honeywellprocess.com/library/support/notifications/Customer/SN2021-02-22-01-Experion-C300-CCL.pdf",
      "tags": [
        "Product"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-278-04",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.honeywellprocess.com/library/support/notifications/Customer/SN2021-02-22-01-Experion-C300-CCL.pdf",
      "tags": [
        "Product"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-23"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to relative path traversal, which may allow an attacker access to unauthorized files and directories."
    },
    {
      "lang": "es",
      "value": "Los controladores Honeywell Experion PKS C200, C200E, C300 y ACE son vulnerables al Path Traversal relativa, lo que puede permitir que un atacante acceda a archivos y directorios no autorizados."
    }
  ],
  "lastModified": "2026-06-17T04:02:01.513",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:c200_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "89205AE1-0EE7-4665-8FE6-5312EAD5FB2D"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:c200:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B3F154A3-2438-4420-8B6E-E0521376714E"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:c200e_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3B06800D-443D-4237-8E91-98735E5EA148"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:c200e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6ACB0AD6-5A19-4DEC-9F47-03EC6FA80AC0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:c300_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7C79B7D1-630B-4723-BFCA-66F03F93D1FB"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:c300:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CEA14D67-E320-490E-92E6-CC135EBBA245"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:honeywell:application_control_environment_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "83F4F4B6-E05B-43B9-96ED-02919E42AFCC"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:honeywell:application_control_environment:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7C79B55A-11AB-441E-A544-9678616E9BA4"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}