CVE-2021-34576
Estado: ModificadaMedia (4.3)—
In Kaden PICOFLUX Air in all known versions an information exposure through observable discrepancy exists. This may give sensitive information (water consumption without distinct values) to third parties.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 4.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.36%
- Percentil entre todas las CVEs puntuadas: 28
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-203
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-34576",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.3,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "info@cert.vde.com",
"affectedData": [
{
"vendor": "Kaden",
"product": "PICOFLUX AiR",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
]
}
],
"published": "2021-09-16T13:15:14.817",
"references": [
{
"url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34576.en",
"tags": [
"Third Party Advisory"
],
"source": "info@cert.vde.com"
},
{
"url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34576.en",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"description": [
{
"lang": "en",
"value": "CWE-203"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Kaden PICOFLUX Air in all known versions an information exposure through observable discrepancy exists. This may give sensitive information (water consumption without distinct values) to third parties."
},
{
"lang": "es",
"value": "En Kaden PICOFLUX Air en todas las versiones conocidas se presenta una exposición de información mediante una discrepancia observable. Esto puede dar información confidencial (consumo de agua sin valores distintos) a terceros"
}
],
"lastModified": "2026-06-17T03:56:09.600",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:kadenvodomery:picoflux_air_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E997A4A7-18BF-4D96-9BA4-693546CC9B89"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:kadenvodomery:picoflux_air:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "01C6CD16-D38E-4B3C-9FBF-BF017B41D021"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "info@cert.vde.com"
}