« Volver al listado

CVE-2021-34332

Estado: ModificadaMedia (5.5)—

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to denial of service condition. An attacker could leverage this vulnerability to consume excessive resources. (CNVD-C-2021-79300)

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-34332",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "JT2Go",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V13.2"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V13.2"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-07-13T11:15:13.417",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-835"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to denial of service condition. An attacker could leverage this vulnerability to consume excessive resources. (CNVD-C-2021-79300)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2). La biblioteca BMP_Loader.dll de las aplicaciones afectadas no comprueba apropiadamente los datos suministrados por el usuario cuando se analizan los archivos BMP. Un archivo de entrada malformado podría resultar en una condición de bucle infinito que conlleva una condición de denegación de servicio. Un atacante podría aprovechar esta vulnerabilidad para consumir  recursos excesivos. (CNVD-C-2021-79300)"
    }
  ],
  "lastModified": "2026-06-17T03:55:40.423",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CAFFF33E-9758-4C92-B2BF-2CF0E2EA6217",
              "versionEndExcluding": "13.2.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6C391214-6E11-4196-BF69-5327069864D8",
              "versionEndExcluding": "13.2.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}