CVE-2021-32002
Estado: ModificadaBaja (3.3)—
Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 3.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-200, CWE-284
- NVD-CWE-Other
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-32002",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 2.1,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "VulnerabilityReporting@secomea.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.3,
"attackVector": "LOCAL",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "VulnerabilityReporting@secomea.com",
"affectedData": [
{
"vendor": "Secomea",
"product": "SiteManager",
"versions": [
{
"status": "affected",
"version": "All",
"lessThan": "9.5",
"versionType": "custom"
}
],
"platforms": [
"Hardware"
]
}
]
}
],
"published": "2021-08-05T21:15:11.970",
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory",
"tags": [
"Vendor Advisory"
],
"source": "VulnerabilityReporting@secomea.com"
},
{
"url": "https://www.secomea.com/support/cybersecurity-advisory",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "VulnerabilityReporting@secomea.com",
"description": [
{
"lang": "en",
"value": "CWE-200"
},
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware."
},
{
"lang": "es",
"value": "Una vulnerabilidad de control de acceso inapropiado en el servicio web de Secomea SiteManager permite a un atacante local sin credenciales recopilar información de red y configuración del SiteManager. Este problema afecta a: Secomea SiteManager Todas las versiones anteriores a 9.5 en Hardware"
}
],
"lastModified": "2026-06-17T03:52:39.397",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:secomea:sitemanager_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7A1C871A-C158-49A3-B912-14615562068D",
"versionEndExcluding": "9.5.621256022"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:secomea:sitemanager:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5DEE66B6-F0A6-4172-8795-48A6DF6A61E9"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "VulnerabilityReporting@secomea.com"
}