CVE-2021-31346
Estado: ModificadaCrítica (9.1)—
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
- Puntuación base: 9.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.97%
- Percentil entre todas las CVEs puntuadas: 80
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (11)
Siemens — Apogee Modular Building Controller FirmwareSiemens — Apogee Modular Equiment Controller FirmwareSiemens — Apogee PXC Compact FirmwareSiemens — Apogee PXC Modular FirmwareSiemens — Capital VstarSiemens — Nucleus NETSiemens — Nucleus Readystart V3Siemens — Nucleus Readystart V4Siemens — Nucleus Source CodeSiemens — Talon TC Compact FirmwareSiemens — Talon TC Modular Firmware
CWE
- CWE-1284
Referencias
- https://cert-portal.siemens.com/productcert/html/ssa-044112.html
- https://cert-portal.siemens.com/productcert/html/ssa-114589.html
- https://cert-portal.siemens.com/productcert/html/ssa-223353.html
- https://cert-portal.siemens.com/productcert/html/ssa-620288.html
- https://cert-portal.siemens.com/productcert/html/ssa-845392.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-31346",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.4,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 4.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 4.2,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.1,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Capital Embedded AR Classic 431-422",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Capital Embedded AR Classic R20-11",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2303",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "PLUSCONTROL 1st Gen",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMOTICS CONNECT 400",
"versions": [
{
"status": "affected",
"version": "All versions < V0.5.0.0"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMOTICS CONNECT 400",
"versions": [
{
"status": "affected",
"version": "All versions < V1.0.0.0"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2021-11-09T12:15:09.200",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-1284"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en APOGEE MBC (PPC) (BACnet) (Todas las versiones), APOGEE MBC (PPC) (P2 Ethernet) (Todas las versiones), APOGEE MEC (PPC) (BACnet) (Todas las versiones), APOGEE MEC (PPC) (P2 Ethernet) (Todas las versiones), APOGEE PXC Compact (BACnet) (Todas las versiones anteriores a V3. 5.4), APOGEE PXC Compact (P2 Ethernet) (Todas las versiones anteriores a V2.8.19), APOGEE PXC Modular (BACnet) (Todas las versiones anteriores a V3.5. 4), APOGEE PXC Modular (P2 Ethernet) (Todas las versiones anteriores a V2.8.19), Capital VSTAR (Todas las versiones con opciones de Ethernet activadas), Desigo PXC00-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC00-U (Todas las versiones posteriores o iguales a V2. 3 y anteriores a V6.30.016), Desigo PXC001-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC100-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC12-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30. 016), Desigo PXC128-U (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC200-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC22-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC22.1-E. D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC36.1-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC50-E.D (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Desigo PXC64-U (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30. 016), Desigo PXM20-E (Todas las versiones posteriores o iguales a V2.3 y anteriores a V6.30.016), Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.4), Nucleus ReadyStart V4 (Todas las versiones anteriores a V4.1. 1), Nucleus Source Code (Todas las versiones), PLUSCONTROL 1st Gen (Todas las versiones), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.5.0.0), TALON TC Compact (BACnet) (Todas las versiones anteriores a V3.5.4), TALON TC Modular (BACnet) (Todas las versiones anteriores a V3.5.4). La longitud total de una carga útil ICMP (fijada en la cabecera IP) no está marcada. Esto puede conducir a varios efectos secundarios, incluyendo la fuga de información y las condiciones de denegación de servicio, dependiendo de la organización del buffer de red en la memoria. (FSMD-2021-0007)"
}
],
"lastModified": "2026-06-17T03:51:35.280",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3EC45D63-0FB7-4995-AF45-B41F6EF6A9E2"
},
{
"criteria": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7A987CFB-4A41-4F82-8C7F-31DE8F0650DE"
},
{
"criteria": "cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "769372D0-68B3-47F3-B13B-43EAAF7E822D",
"versionEndExcluding": "2017.02.1"
},
{
"criteria": "cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BEB581B9-8F63-4117-A420-C271E5FF6EC6",
"versionEndExcluding": "4.1.1"
},
{
"criteria": "cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "07DAF9C3-B56A-4F40-B90B-D0DE96869A44"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "60FAD4D8-54FA-4721-954E-4AD77020B189"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B5F978E7-3DD9-4948-BFFB-E7273003477B"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "ACCB699F-4F10-47BD-8890-047380972BE1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7945BF7D-AB3A-4285-9C58-D56149ADFC15"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "105A6FFB-1176-4021-868D-3D6CE77113B2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8E2E8B0F-EBBC-4BCC-BE2A-20DCB506DF7F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C6BE40AF-B7A4-498A-943E-11AA9393A3D6"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D9485F0B-03E0-4442-B615-2DA91AE1CD00"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0CA14719-C655-4BED-AE8D-B9C983847AE4"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "46D32EF0-8AEC-4594-8928-45F34DC60600"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1F3470FD-BEBE-465F-A189-F4CEDD0F6815"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "00C647D8-1725-42FA-8042-6C413EE67573"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}