CVE-2021-28684
Estado: ModificadaMedia (4.3)—
The XML parser used in ConeXware PowerArchiver before 20.10.02 allows processing of external entities, which might lead to exfiltration of local files over the network (via an XXE attack).
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
- Puntuación base: 4.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.92%
- Percentil entre todas las CVEs puntuadas: 59
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-611
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-28684",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2021-06-21T13:15:08.037",
"references": [
{
"url": "https://peterka.tech/blog/posts/cve-2021-28684/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.powerarchiver.com",
"tags": [
"Product"
],
"source": "cve@mitre.org"
},
{
"url": "https://peterka.tech/blog/posts/cve-2021-28684/",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.powerarchiver.com",
"tags": [
"Product"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-611"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The XML parser used in ConeXware PowerArchiver before 20.10.02 allows processing of external entities, which might lead to exfiltration of local files over the network (via an XXE attack)."
},
{
"lang": "es",
"value": "El analizador XML usado en ConeXware PowerArchiver versiones anteriores a 20.10.02, permite el procesamiento de entidades externas, lo que podría conllevar a la exfiltración de archivos locales a través de la red (por medio de un ataque de tipo XXE)"
}
],
"lastModified": "2026-06-17T03:46:47.433",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:powerarchiver:powerarchiver:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D972881A-E30D-42BF-88F0-811CED3054E5",
"versionEndExcluding": "20.10.02"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}