CVE-2021-27385
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl.
Leer descripción completaMostrar menos
SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.56%
- Percentil entre todas las CVEs puntuadas: 85
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (18)
CWE
- CWE-400
- CWE-835
Referencias
- https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12
- https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-27385",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2021-27385",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-02T19:07:48.517703Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Update 6"
}
]
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V16 Update 4"
}
]
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Update 6"
}
]
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V16 Update 4"
}
]
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Update 6"
}
]
},
{
"vendor": "Siemens",
"product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"versions": [
{
"status": "affected",
"version": "All versions < V16 Update 4"
}
]
},
{
"vendor": "Siemens",
"product": "SIMATIC WinCC Runtime Advanced V15",
"versions": [
{
"status": "affected",
"version": "All versions < V15.1 Update 6"
}
]
},
{
"vendor": "Siemens",
"product": "SIMATIC WinCC Runtime Advanced V16",
"versions": [
{
"status": "affected",
"version": "All versions < V16 Update 4"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS GH150",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS GL150 (with option X30)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS GM150 (with option X30)",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS SH150",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS SL150",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS SM120",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS SM150",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "Siemens",
"product": "SINAMICS SM150i",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
]
}
],
"published": "2021-05-12T14:15:11.727",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-835"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opción X30) (Todas las versiones), SINAMICS GM150 (con opción X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Un atacante remoto podría enviar paquetes especialmente diseñados al manejador de diseño de dispositivos SmartVNC en el lado del cliente, lo que podría influir en la cantidad de recursos consumidos y dar lugar a una condición de denegación de servicio (bucle infinito)"
}
],
"lastModified": "2026-06-17T03:44:45.383",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA",
"versionEndExcluding": "16"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "79407355-4181-4082-A661-C27734D95363"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685"
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}