« Volver al listado

CVE-2021-27035

Estado: ModificadaAlta (7.8)—

A maliciously crafted TIFF, TIF, PICT, TGA, or DWF files in Autodesk Design Review 2018, 2017, 2013, 2012, 2011 can be forced to read beyond allocated boundaries when parsing the TIFF, PICT, TGA or DWF files. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-27035",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@autodesk.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Autodesk Design Review",
          "versions": [
            {
              "status": "affected",
              "version": "2018, 2017, 2013, 2012, 2011"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-07-09T15:15:07.877",
  "references": [
    {
      "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "psirt@autodesk.com"
    },
    {
      "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A maliciously crafted TIFF, TIF, PICT, TGA, or DWF files in Autodesk Design Review 2018, 2017, 2013, 2012, 2011 can be forced to read beyond allocated boundaries when parsing the TIFF, PICT, TGA or DWF files. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Un archivo TIFF, TIF, PICT, TGA o DWF malintencionado en Autodesk Design Review 2018, 2017, 2013, 2012, 2011 puede ser forzado a leer más allá de los límites asignados al analizar los archivos TIFF, PICT, TGA o DWF. Esta vulnerabilidad en conjunto con otras vulnerabilidades podría llevar a la ejecución de código en el contexto del proceso actual"
    }
  ],
  "lastModified": "2026-06-17T03:44:10.027",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2011:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "83CF6CDF-806C-4DC5-B572-C1C2BC2C25F2"
            },
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2012:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2A78B6F8-DF84-4E6C-A247-0F6D2F8CA679"
            },
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2013:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DCD2CA9B-16E1-4BE7-A4E1-A9817A503958"
            },
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2017:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "31F2529F-ECF0-4568-BBDC-82B396A52332"
            },
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "213232B9-A40B-436D-A66A-B65C49D59BE6"
            },
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2018:hotfix:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2D0CF4DC-ACA5-41D0-B28E-CEB5D2C96F71"
            },
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2018:hotfix2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "84ED1789-A17F-48F7-A152-09D2A5C59254"
            },
            {
              "criteria": "cpe:2.3:a:autodesk:design_review:2018:hotfix3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "74819924-EB63-4BBF-9986-FEF6100EEE15"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "psirt@autodesk.com"
}