CVE-2021-25666
Estado: ModificadaMedia (4.3)—
A vulnerability has been identified in SCALANCE W780 and W740 (IEEE 802.11n) family (All versions < V6.3). Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
- Puntuación base: 4.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.69%
- Percentil entre todas las CVEs puntuadas: 51
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-770
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-25666",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.3,
"accessVector": "ADJACENT_NETWORK",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.5,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SCALANCE W780 and W740 (IEEE 802.11n) family",
"versions": [
{
"status": "affected",
"version": "All versions < V6.3"
}
]
}
]
}
],
"published": "2021-02-09T18:15:51.573",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686152.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-07",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686152.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-07",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-770"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE W780 and W740 (IEEE 802.11n) family (All versions < V6.3). Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia SCALANCE W780 y W740 (IEEE 802.11n) (todas las versiones anteriores a V6.3). El envío de paquetes especialmente diseñados por medio del protocolo ARP hacia un dispositivo afectado podría causar una denegación de servicio parcial, impidiendo al dispositivo funcionar normalmente durante un corto período de tiempo"
}
],
"lastModified": "2026-06-17T03:42:19.073",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w780_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BCE9B4EC-DF55-4F8A-B130-C0F8F286441C",
"versionEndExcluding": "6.3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w780:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CB406941-2C32-4551-8C1C-9E8DC4157E73"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w740_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "00F55236-C25F-4F93-B74C-AE75EEDBD388",
"versionEndExcluding": "6.3"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w740:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5BFC9F18-3070-4F23-88D9-F40CDF884174"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}