A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-22826",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 6.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-01-28T20:15:10.677",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions"
    },
    {
      "lang": "es",
      "value": "Una CWE-20: Se presenta una vulnerabilidad de Comprobación de Entrada Inapropiada que podría causar una ejecución de código arbitrario cuando el usuario visita una página que contiene la carga útil inyectada. Esta CVE es diferente de CVE-2021-22827. Producto afectado: EcoStruxure? Power Monitoring Expert versiones 9.0 y anteriores"
    }
  ],
  "lastModified": "2026-06-17T03:37:52.090",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A0DFDD3F-37A7-42B1-88E2-BDC969572CD5",
              "versionEndIncluding": "9.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}