« Volver al listado

CVE-2021-22799

Estado: ModificadaBaja (3.8)—

A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-22799",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 2.1,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 3.8,
          "attackVector": "LOCAL",
          "baseSeverity": "LOW",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2022-01-28T20:15:09.770",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-331"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1"
    },
    {
      "lang": "es",
      "value": "Una CWE-331: Se presenta una vulnerabilidad de Entropía Insuficiente que podría causar una conexión no intencionada desde una red interna a una red externa cuando un atacante consigue descifrar la contraseña del proxy SESU desde el registro. Producto afectado: Schneider Electric Software Update, V2.3.0 hasta V2.5.1"
    }
  ],
  "lastModified": "2026-06-17T03:37:48.530",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:software_update:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BCC1E042-7930-4E73-A79D-51B7A7777CBA",
              "versionEndExcluding": "2.5.2",
              "versionStartIncluding": "2.3.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}