CVE-2021-22797
Estado: ModificadaAlta (7.8)—
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 26%
- Percentil entre todas las CVEs puntuadas: 98
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-22
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-22797",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EcoStruxure Control Expert",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "V15.0 SP1",
"versionType": "custom"
}
]
},
{
"vendor": "Schneider Electric",
"product": "EcoStruxure Process Expert",
"versions": [
{
"status": "affected",
"version": "unspecified",
"lessThan": "2020",
"versionType": "custom"
}
]
},
{
"vendor": "Schneider Electric",
"product": "SCADAPack RemoteConnect for x70",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
]
}
],
"published": "2022-04-13T16:15:09.370",
"references": [
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)"
},
{
"lang": "es",
"value": "Una CWE-22: Se presenta una vulnerabilidad de Limitación inadecuada de un nombre de ruta a un directorio restringido (\" Salto de Ruta\") que podría causar la implementación de scripts maliciosos en una ubicación no autorizada y puede resultar en una ejecución de código en la estación de trabajo de ingeniería cuando es cargado un archivo de proyecto malicioso en el software de ingeniería. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores, incluido el antiguo Unity Pro), EcoStruxure Process Expert (versiones 2020 y anteriores, incluido el antiguo HDCS), SCADAPack RemoteConnect para x70 (Todas las versiones)"
}
],
"lastModified": "2026-06-17T03:37:48.303",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314",
"versionEndExcluding": "15.1"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB",
"versionEndExcluding": "2021"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678"
},
{
"criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0"
},
{
"criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1"
},
{
"criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3"
},
{
"criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}