CVE-2021-22735
Estado: ModificadaAlta (7.2)—
Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.00%
- Percentil entre todas las CVEs puntuadas: 62
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-347
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-22735",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "n/a",
"product": "homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior",
"versions": [
{
"status": "affected",
"version": "homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior"
}
]
}
]
}
],
"published": "2021-05-26T20:15:09.063",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-347"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de Comprobación Inapropiada de la Firma Criptográfica en homeLYnk (Wiser For KNX) y spaceLYnk versiones V2.60 y anteriores, que podría permitir una ejecución de código remota cuando un código no autorizado es copiado en el dispositivo"
}
],
"lastModified": "2026-06-17T03:37:40.827",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "317276F1-1B80-4CBC-92A0-8F1E7561FA16",
"versionEndIncluding": "2.6.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F7B2FBBD-C461-47EF-A912-E445C063DED9"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:homelynk_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5E04856B-1BBF-4E36-BB26-4E03F603F645",
"versionEndIncluding": "2.6.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:homelynk:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E5369C17-DEC4-4B14-ACFB-6CCCB6C04F1D"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}