CVE-2021-22703
Estado: ModificadaAlta (7.5)—
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.60%
- Percentil entre todas las CVEs puntuadas: 47
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (10)
Schneider-electric — Powerlogic Ion7400 FirmwareSchneider-electric — Powerlogic Ion7650 FirmwareSchneider-electric — Powerlogic Ion8300 FirmwareSchneider-electric — Powerlogic Ion8400 FirmwareSchneider-electric — Powerlogic Ion8500 FirmwareSchneider-electric — Powerlogic Ion8600 FirmwareSchneider-electric — Powerlogic Ion8650 FirmwareSchneider-electric — Powerlogic Ion8800 FirmwareSchneider-electric — Powerlogic Ion9000 FirmwareSchneider-electric — Powerlogic Pm8000 Firmware
CWE
- CWE-319
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-22703",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2021-22703",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-05-29T13:32:50.609050Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "n/a",
"product": "PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
}
]
}
]
}
],
"published": "2021-02-19T16:15:13.157",
"references": [
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device."
},
{
"lang": "es",
"value": "Una CWE-319: Se presenta una vulnerabilidad de transmisión de información confidencial en texto sin cifrar en PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 y PM800 (consulte la notificación para las versiones afectadas), que podría causar una divulgación de las credenciales del usuario cuando un actor malicioso intercepta el tráfico de red HTTP entre un usuario y el dispositivo"
}
],
"lastModified": "2026-06-17T03:37:35.733",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DCE7015C-02DD-44A1-ADEE-5E71CE312266",
"versionEndExcluding": "3.0.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7650_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C1647241-A18D-4E4C-A118-8809EA625FC7"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7650:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0DF2D964-79EF-43F2-9AC6-D263F75BAFA0"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8600_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DB6B0276-AB51-4B8F-B2A7-85EDD56C9E7C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8600:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "324CF58A-753C-4D9C-8E72-FC8EE26EDA0D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5D91486A-36CD-49A9-8A45-EDAA75F05E50",
"versionEndIncluding": "4.31.2"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C95DCE16-BAA5-46DD-835B-2299376387CD"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "46E8E79E-6DA7-4094-9622-3B91D5913493"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "32067EA8-5153-4A00-9DE8-C4BEC42C00A6",
"versionEndExcluding": "3.0.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6718EAAA-074D-4807-AC2D-DD0A06D397FB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E5A75862-E1AC-4C6E-83AD-DE5FCD8BA50D",
"versionEndExcluding": "3.0.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8300_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1047C892-B7F5-49FB-AB36-8E8061A58037"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8300:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F01E9FE2-4110-4A6D-99F3-49784808D951"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8400_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "70BAC583-6101-4F26-A264-26E5D69E9188"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8400:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "82527983-6167-4D7B-A70A-D1A814ED3D06"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8500_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "768FB179-B6D7-457C-9795-310400460F6E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "75E37742-CFF9-4F80-9B6A-0D4F5AD23112"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}