CVE-2021-21904
Estado: ModificadaAlta (7.2)—
A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors’ iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.82%
- Percentil entre todas las CVEs puntuadas: 86
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-22
- CWE-22
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-21904",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 9.1,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 2.3
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Garrett Metal Detectors",
"versions": [
{
"status": "affected",
"version": "Garrett Metal Detectors iC Module CMA Version 5.0"
}
]
}
]
}
],
"published": "2021-12-22T19:15:09.743",
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors’ iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability"
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de salto de directorio en el comando CMA CLI setenv de iC Module CMA de Garrett Metal Detectors versión 5.0. Un atacante puede proporcionar una entrada maliciosa para desencadenar esta vulnerabilidad"
}
],
"lastModified": "2026-06-17T03:36:20.073",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}