« Volver al listado

CVE-2021-21543

Estado: ModificadaMedia (4.8)—

Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-21543",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 3.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "LOW",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 6.8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 4.8,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 1.7
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 4.8,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 1.7
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "Integrated Dell Remote Access Controller (iDRAC)",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified",
              "lessThan": "4.40.00.00",
              "versionType": "custom"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-04-30T21:15:08.860",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/000185293",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/000185293",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
    },
    {
      "lang": "es",
      "value": "Dell EMC iDRAC9 versiones anteriores a 4.40.00.00, contienen múltiples vulnerabilidades de tipo cross-site scripting almacenado. Un usuario malicioso autenticado remoto con privilegios elevados podría explotar estas vulnerabilidades para almacenar código HTML o JavaScript malicioso por medio de múltiples parámetros afectados. Cuando los usuarios víctimas acceden a los datos enviados por medio de sus navegadores, el navegador web ejecuta el código malicioso en el contexto de la aplicación vulnerable."
    }
  ],
  "lastModified": "2026-06-17T03:35:44.907",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5E9ED974-1468-4B8B-B82E-5E0340C2601B",
              "versionEndExcluding": "4.40.00.00"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}