« Volver al listado

CVE-2020-8601

Estado: ModificadaAlta (7.8)—

Trend Micro Vulnerability Protection 2.0 is affected by a vulnerability that could allow an attack to use the product installer to load other DLL files located in the same directory.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-8601",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.6,
          "accessVector": "LOCAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 3.9,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "security@trendmicro.com",
      "affectedData": [
        {
          "vendor": "Trend Micro",
          "product": "Trend Micro Vulnerability Protection",
          "versions": [
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-02-20T23:15:20.897",
  "references": [
    {
      "url": "https://success.trendmicro.com/solution/000241963",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security@trendmicro.com"
    },
    {
      "url": "https://success.trendmicro.com/solution/000241963",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Trend Micro Vulnerability Protection 2.0 is affected by a vulnerability that could allow an attack to use the product installer to load other DLL files located in the same directory."
    },
    {
      "lang": "es",
      "value": "Trend Micro Vulnerability Protection versión 2.0, está afectado por una vulnerabilidad que podría permitir que un ataque use el instalador del producto para cargar otros archivos DLL localizados en el mismo directorio."
    }
  ],
  "lastModified": "2026-06-17T03:26:37.573",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:trendmicro:vulnerability_protection:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "60A4CFF5-6B1E-4DB7-A1F7-4E8A4F0B9D75"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "security@trendmicro.com"
}